	CAB30L-32 Residual Current Breakers with Overload Protection RCBo is be used for protection against overload and short-circuit currents; protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts; command and isolation of resistive and inductive loads. Suitable for commercial and industrial applications.
	Compliant standard: IEC61009-1 
2. Type designation
	
	3  Technical data
| Specifications | |
| 
				 
					Rated voltage(v) :  | 
			
				 
					230V~  | 
		
| 
				 
					Rated current(A) :  | 
			
				 
					6A、10A、16A、20A、25A、32A  | 
		
| 
				 
					Rated sensitivity lrn (mA)  | 
			
				 
					30mA、100mA、300mA  | 
		
| 
				 
					Rated  residual non-operating current  | 
			
				 
					0.5lrn  | 
		
| 
				 
					Poles :  | 
			
				 
					1P+N  | 
		
| 
				 
					Rated breaking capacity  lcu(A)  | 
			
				 
					3000A  | 
		
| 
				 
					Tripping time  | 
			
				 
					Table 1  | 
		
| 
				 
					Tripping characteristics  | 
			
				 
					Table 2  | 
		
| 
				 
					Mechanical life & Electrical life  | 
			
				 
					Mechanical life:4000 ;Electrical life: :2000  | 
		
| 
				 
					Nominal cross section area (mm2)   | 
			
				 
					10mm2  | 
		
| 
				 
					Pollution degree  | 
			
				 
					2  | 
		
| 
				 
					Protection class  | 
			
				 
					IP20  | 
		
| 
				 
					Overvoltage category   | 
			
				 
					Ⅱ  | 
		
	Table 1   Tripping time: 
| ln (A) | l(n (mA) | Operating time:(s) | ||
| 
				 
					l(n  | 
			
				 
					2l(n  | 
			
				 
					5l(n  | 
		||
| 
				 
					6~32  | 
			
				 
					30、100、300  | 
			
				 
					0.2  | 
			
				 
					0.1  | 
			
				 
					0.04  | 
		
	Table 2  Tripping characteristics :
| Curve | Test current | Initial status | Tripping time | Test result | Remarks | 
| 
				 
					B,C,D  | 
			
				 
					1.13In  | 
			
				 
					Cold  | 
			
				 
					t≤1h  | 
			
				 
					Non-tripping  | 
			
				 
  | 
		
| 
				 
					B,C,D  | 
			
				 
					1.45In  | 
			
				 
					Following No.1 test  | 
			
				 
					t<1h  | 
			
				 
					tripping  | 
			
				 
					Current smoothly rises to specified value in 5s  | 
		
| 
				 
					B,C,D  | 
			
				 
					2.55In  | 
			
				 
					Cold  | 
			
				 
					1s<t<60s(≤32A) 
					1s<t<120s(>32A)  | 
			
				 
					tripping  | 
			
				 
  | 
		
| 
				 
					B 
					C 
					D  | 
			
				 
					3In 
					5In 
					10In  | 
			
				 
					Cold  | 
			
				 
					t≤0.1s  | 
			
				 
					Non-tripping  | 
			
				 
					Switch on the power supply by closing the auxiliary switch  | 
		
| 
				 
					B 
					C 
					D  | 
			
				 
					5In 
					10In 
					20In  | 
			
				 
					Cold  | 
			
				 
					t<0.1s  | 
			
				 
					tripping  | 
			
				 
					Switch on the power supply by closing the auxiliary switch  | 
		
| 
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
		
| 
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
		
| 
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
			
				 
  | 
		
	4  Operating conditions.
	4.1  Ambient  temp. range:-5℃~+40 ℃,average temperature in 24 hours not exceed +35℃
	4.2  Altitude:≤ 2000m;
	4.3  At mounting site, relative humidity not exceed 50% at the max temperature of +40 ℃,higher relative humidity is allowable under lower temperature, for example ,RH could be 90% at +20 ℃
	4.4  Mounting type :  Din rail embedded(TH35-7.5)
	4.5 Installation conditions
	Any direction of the outer magnetic field of the installation site should not exceed 5 times than earth's magnetic field; residual current operated circuit breaker should be mounted vertically, all places inclination no more than 5 °,power position above the handle  , the installation place should be no significant impact and vibration. 
5. Dimensions ( unit:mm)
	