CAB30aL-40 Residual Current Breakers with Overload Protection RCBo is be used for protection against overload and short-circuit currents; protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts; command and isolation of resistive and inductive loads. Suitable for commercial and industrial applications.
Compliant standard: IEC61009-1
2. Type designation
3 Technical data
Specifications | |
Rated voltage(v) : |
230V~ |
Rated current(A) : |
6A、10A、16A、20A、25A、32A、40A |
Rated sensitivity lrn (mA) |
30mA |
Rated residual non-operating current |
15mA |
Poles : |
1P+N |
Rated breaking capacity : lcu(A) |
3000A |
Operating time: |
≤0.1s |
Tripping characteristics : |
Table 1 |
Mechanical life & Electrical life: |
Mechanical life:4000 ;Electrical life: :2000 |
Nominal cross section area (mm2) : |
10mm2 |
Pollution degree: |
2 |
Protection class: |
IP20 |
Overvoltage category : |
Ⅱ |
Table 1 Tripping characteristic :
Type | Test current | Initial status | Tripping time | Test result | Remarks |
B,C,D |
1.13In |
Cold |
t≤1h |
Non-tripping |
|
B,C,D |
1.45In |
Following No.1 test |
t<1h |
tripping |
Current smoothly rises to specified value in 5s |
B,C,D |
2.55In |
Cold |
1s<t<60s(≤32A)
1s<t<120s(>32A) |
tripping |
|
B
C
D |
3In
5In
10In |
Cold |
t≤0.1s |
Non-tripping |
Switch on the power supply by closing the auxiliary switch |
B
C
D |
5In
10In
20In |
Cold |
t<0.1s |
tripping |
Switch on the power supply by closing the auxiliary switch |
Note: The terminology “Cold ” means that the test is performed at the base calibration temperature with no load prior to the test.
4 Operating conditions.
4.1 : Ambient temp. range:-5℃~+40 ℃,average temperature in 24 hours not exceed +35℃
4.2 : Altitude:≤ 2000m;
4.3 : At mounting site, relative humidity not exceed 50% at the max temperature of +40 ℃,higher relative humidity is allowable under lower temperature, for example ,RH could be 90% at +20 ℃
4.4 : Mounting type : Din rail embedded(TH35-7.5)
4.5 Installation conditions
Any direction of the outer magnetic field of the installation site should not exceed 5 times than earth's magnetic field; residual current operated circuit breaker should be mounted vertically, all places inclination no more than 5 °,power position above the handle , the installation place should be no significant impact and vibration.
5 Dimensions(unit:mm)